Seite 1 - LECTROSONICS, INC

H185 PLUG-ON TRANSMITTER OPERATING INSTRUCTIONS and trouble-shooting guide LECTROSONICS, INC. Rio Rancho, NM

Seite 2 - TABLE OF CONTENTS

SERVICE AND REPAIR If your system malfunctions, you should attempt to correct or isolate the trouble before concluding that the equipment needs repai

Seite 3

LIMITED ONE YEAR WARRANTY The equipment is warranted for one year from date of purchase against defects in materials or workmanship provided it was pu

Seite 4 - CONTROLS AND FUNCTIONS

INTRODUCTION Thank you for selecting the Lectrosonics Professional Series wireless microphone system. This system represents well over 10 years of ma

Seite 5

GENERAL TECHNICAL DESCRIPTION The H185 transmitter is comprised of four major functional subsystems: the input compressor, the mic preamp/gain contro

Seite 6

CONTROLS AND FUNCTIONS The H185 may be used with a wide variety of microphones. The 3-pin XLR type connector on the H185 allows the transmitter to b

Seite 7 - BATTERY REPLACEMENT

The POWER LED is connected to a precision battery test circuit that continuously monitors battery voltage. The LED is at full brightness with a new 9

Seite 8 - TROUBLESHOOTING

OPERATING INSTRUCTIONS 1) Insert the H185 into the selected microphone. Listen for the "click" that indicates the H185 has locked on to th

Seite 9 - SPECIFICATIONS AND FEATURES

The LEVEL LED turns on at -10dB below full deviation. The LIMIT LED turns on at full deviation and indicates that the input shunt compressor is opera

Seite 10 - RETURNING UNITS FOR REPAIR

TROUBLESHOOTING Before going through the following chart, be sure that you have a good battery in the transmitter the red power LED on the transmitte

Seite 11 - LIMITED ONE YEAR WARRANTY

SPECIFICATIONS AND FEATURES Operating frequencies: 150 to 216 MHz RF Power output: 50mW Deviation: +/- 15kHz Spurious radiation: 55dB below carri